In short.
DDC CO2 Carbon Footprint Calculator is an AI assistant skill for construction analysts and developers estimating material emissions, but its default factors and automatic material matching need review before project reporting. Its embedded Python implementation multiplies quantities by carbon factors, groups results and exports Excel worksheets. The defaults cover the product stage only; factor provenance, incomplete-input handling and broader life-cycle coverage have material limitations. Runtime behavior, accuracy and host compatibility remain untested.
Researched and written by an AI model and checked by a second AI model. How it works
Covers SKILL.md, claw.json and instructions.md in 1_DDC_Toolkit/BIM-Analysis/co2-carbon-footprint at commit 410ed1e71e4a5c6fd231afd0c8d1e586a9f546e8, plus the repository-level LICENSE and NOTICE.md. Other skills, the referenced book, external standards and EPD databases are outside this scope. The findings describe the supplied text and code; installation, execution, performance, numerical validation, host compatibility and real-project use were not tested.
The overview
Identity
The co2-carbon-footprint folder belongs to DataDrivenConstruction's DDC Skills for AI Agents in Construction repository. It contains SKILL.md with an embedded Python implementation, instructions.md defining the assistant's task, and claw.json describing the package. The manifest identifies datadrivenconstruction as the author and instructions.md as the entry point.
The version-specific source folder is available at [https://github.com/datadrivenconstruction/DDC_Skills_for_AI_Agents_in_Construction/tree/410ed1e71e4a5c6fd231afd0c8d1e586a9f546e8/1_DDC_Toolkit/BIM-Analysis/co2-carbon-footprint].
Assessment
The strongest fit is an exploratory calculation or a starting point for a reviewed project-specific implementation. Its visible quantity-times-factor method is straightforward to inspect, but the generic factor labels do not identify verifiable environmental product declarations, or EPDs.
The source references EN 15978 and sustainability reporting, but those references do not establish standards compliance. The example's 500 kg CO2e/m² threshold is an illustrative constant; the supplied evidence does not establish it as an applicable LEED or BREEAM requirement.
Users
BIM analysts, sustainability specialists and construction developers with prepared material quantities are the likely users. BIM means building information modelling; this code works with tabular quantities rather than directly reading building geometry.
Beginners will need help preparing consistent material names, units and factors. Developers can adapt the classes and exports, while a qualified specialist should review the project assumptions and interpretation of estimates.
Capabilities
The supplied code calculates element-level kg CO2e, totals in kilograms and tonnes, and breakdowns by material, category, life-cycle stage and building level. A supplied gross floor area enables a kg CO2e/m² intensity calculation. Excel export creates Details and Summary worksheets.
There is no implemented building-system grouping despite the package description mentioning it. The material-comparison example filters concrete and timber rows without calculating a like-for-like design comparison. The assistant instructions mention CSV and JSON, but the supplied file-handling examples demonstrate Excel input and export.
Using it
Requirements
The Python example requires Python 3 and pandas; the demonstrated XLSX workflow also needs openpyxl. Rows need a material name and a usable quantity in the unit expected by the selected factor, such as volume in m³, area in m² or weight in kg. Element identifiers, names and levels support the detailed output.
The manifest declares OpenClaw 0.8.0 as the minimum host version, requests filesystem permission and lists Claude and GPT model families. Metadata lists macOS, Linux and Windows. Exact Python and dependency versions, tested model compatibility and host data-handling behavior are not established.
Mechanism
For each row, the calculator searches for a factor using a case-insensitive exact material match, then a substring match, then the first factor in a guessed material category. It obtains the corresponding quantity and multiplies it by the factor. For mass-based factors, missing weight can be estimated from volume and a hard-coded density, with 1,500 kg/m³ as the fallback.
All 14 default factors cover A1–A3, the product stage. Other life-cycle stages are represented by enumeration values but have no supplied factors. Each calculate_from_dataframe call clears previous results and warnings, so separate stage calculations are not automatically accumulated into a whole-life total.
Setup
Keep SKILL.md, instructions.md and claw.json together when preparing the skill for a compatible host. The supplied folder does not document a complete host installation procedure. For direct Python use, extract the implementation from SKILL.md into a module and provide pandas and openpyxl.
Prepare the quantity table, normalize units and establish appropriate factors before calculating. Replace or edit default factors deliberately: add_coefficient appends entries, while lookup returns the first match, so appending a duplicate material-and-stage factor does not override the existing value.
Example
For a hypothetical row named Concrete C30/37 with volume 10 m³, the embedded default gives 10 × 250 = 2,500 kg CO2e for A1–A3. With a supplied gross floor area of 100 m², that one-row total becomes 25 kg CO2e/m². These are arithmetic illustrations of the source formula, not execution results or validated project estimates.
Assessment & evidence
Limitations
Automatic matching can assign an unintended factor. For example, the material name Steel would match Reinforcement Steel before Structural Steel because of list order. Factor references are generic labels without EPD identifiers, dates or geographic applicability. The uncertainty field defaults to 10% but is never used to calculate uncertainty.
Missing or nonpositive quantities are omitted without warnings. Missing materials and unmatched factors do generate warnings, but those warnings are not exported. Nonnumeric values can raise exceptions, and non-finite numbers are not explicitly rejected. The reported element count therefore does not establish complete input coverage.
Units are assumed rather than converted or checked. Timber defaults include negative product-stage values without an implemented end-of-life balance. Excel output omits factor-source references, uncertainty and life-cycle stage, and its Summary sheet contains only totals and analyzed-element count. No direct IFC or Revit model reader is supplied.
Interpreting the results
A total depends on the supplied quantities, assigned factors, assumed densities and chosen stage boundary. Straightforward multiplication cannot compensate for an incorrect material match or an incomplete schedule.
A negative timber contribution should be interpreted within its stated A1–A3 boundary; it does not establish a net-negative building over its life. Likewise, a zero intensity returned when no positive floor area is supplied represents unavailable normalization, rather than demonstrated zero emissions.
Alternatives
The supplied files name no competing carbon-calculation products and provide no comparative evidence. For the same quantity-times-factor method, an explicit spreadsheet or custom Python calculation using approved material mappings is an alternative approach to consider.
For broader life-cycle reporting, compare candidate tools on traceable EPD data, stage coverage, unit validation and reporting of excluded inputs. No particular alternative's accuracy, compatibility or price is established here.
Evidence
The source consists of SKILL.md, claw.json and instructions.md in the selected folder, together with the repository-level LICENSE and NOTICE.md. The original implementation text is available at [https://raw.githubusercontent.com/datadrivenconstruction/DDC_Skills_for_AI_Agents_in_Construction/410ed1e71e4a5c6fd231afd0c8d1e586a9f546e8/1_DDC_Toolkit/BIM-Analysis/co2-carbon-footprint/SKILL.md].
These files establish the declared interface, embedded formulas, default factors and licensing. They contain no independently identifiable EPD records, execution logs, benchmark results or real-project validation. No code was executed.
Access & freshness
Costs
The MIT licence permits use without a software licence payment. Total operating cost is unknown: the files provide no prices for an AI host, model usage, support, integration work or external EPD access. No runtime, token-use or infrastructure measurements are supplied.
Rights
The repository LICENSE grants MIT rights, including commercial use, modification and redistribution, subject to retaining the copyright and permission notice. NOTICE.md expressly applies MIT to skill instructions and documentation. The copyright identifies DataDrivenConstruction and the year 2026; the licence provides no warranty.
The referenced Data-Driven Construction book has separate all-rights-reserved terms. The skill's MIT licence does not establish reuse rights for external EPD datasets or standards documents.
Version and freshness
The supplied snapshot was captured on 16 November 2026 at repository commit 410ed1e71e4a5c6fd231afd0c8d1e586a9f546e8. claw.json declares skill version 2.0.0. The release date, factor publication dates, subsequent changes and current main-branch contents are unknown from these files; the capture date does not date the underlying carbon data.
Practical next steps
Before relying on project totals, establish the assessment boundary and replace generic defaults with applicable, traceable factors. Review every material assignment, make density assumptions explicit, validate units and numeric values, and reconcile included and excluded rows against the original schedule.
For development, add checks for ambiguous matches, duplicate-factor replacement, missing quantities, non-finite values and accumulation across stages. Preserve factor provenance, stages and warnings in exported reports. Have a qualified specialist review the assumptions and any intended compliance use; the supplied examples do not establish reporting acceptance.